ICM (Obsolete/Legacy Products)
ICM302
ICM (Obsolete/Legacy Products)
ICM302
Nordyne OEM Replacement Control
- Low-cost, time and temperature defrost
- Time and temperature terminate
- Test pins reduce test time by 256X
- Strip heat, reversing valve outputs
- High power output (1 HP fan @ 240 VAC)
- Integral short cycle protection
Input
- Voltage: 18-30 VAC
- Frequency: 50-60 Hz
- Power Consumption: 1 watt maximum
Output
- O, W2:
- Type: Relay
- Form: DPST, normally open
- Rating: 2 amps @ 30 VAC
- DF1, DF2:
- Type: Relay
- Form: SPST, normally closed
- Rating: 1/2 HP @ 240 VAC
- T2:
- Type: Triac
- Rating: 1 amp @ 30 VAC
Time Delays
- Defrost: Fixed at 10 minutes (+/- 5%)
- Interval Between Defrost: Pin selectable (30/60/90 minutes)
- ASC Time: Fixed at 5 minutes (+/- 5%)
- Test Time: Short across test terminals (DFT TST) to reduce time by 256x
- ASC Test Time: Short across test terminals (ASC TST) eliminates anti-short cycle time
Weight/Dimensions
- Weight: 0.1 lb.
- Height: 1″
- Width: 3.5″
- Length: 2.875″
Installation Guide
Download
Nordyne: 621301A, 621579B, 621579C, 917178
ICM Controls: DFORB-AB1004
Recommended Alternative: No suggested alternative