ICM (Obsolete/Legacy Products)
ICM296
ICM (Obsolete/Legacy Products)
ICM296
Carrier OEM Replacement Control
- Spark ignition control module
- For use with intermittent pilot boilers, furnaces and other heating appliances
- Microprocessor-based precision
- 100% safety lockout
- Works with both Natural and LP gas systems
Electrical
- Control Voltage: Line 24V (18-30 VAC) @ 50/60Hz
- Spark Frequency: 60Hz
- Pre-purge: None
- Lockout: 5-6 minutes
- Retries: None
- Relay Contact Rating: 1 amp @ 24 VAC
- Trial for Ignition: 90 seconds
- Flame Failure Response Time: 0.8 seconds max.
Weight/Dimensions
- Weight: 0.45 lb.
- Height: 2″
- Width: 5.375″
- Length: 4″
Carrier: LH33WZ512A
Recommended Alternative:
Feature specific; No suggested alternative