JCI/York OEM Replacement Control
The ICM2901 Intermittent Pilot Gas Ignition Control Module provides easy field replacement of Johnson Control: G770RJA-1, York: 025-27762-700 and comparable ignition controls.
  • Intermittent pilot gas ignition control
  • For use with intermittent pilot boilers, furnaces and other heating appliances
  • Microprocessor-based precision
  • Monitors timing, trial for ignition, rollout switch, flame sensing and lockout
  • Remote flame sensing
  • 100% lockout safety feature
  • Works with both Natural and LP gas systems

Electrical

  • Control Voltage: Line 24 VAC (18-30 VAC) 50/60 Hz
  • Anticipator Setting: 0.3A plus valve load @ 24 VAC
  • Pre-purge: None
  • Trial for Ignition: 85 seconds
  • Retry: None

Environment

  • Operating Temperature:
    • Min. ambient temperature rating is -40°F (-40°C)
    • Max. ambient rating when used with 2.0A main valve is 160°F (71°C)
  • Relative Humidity: 0% to 95% non-condensing
Weight/Dimensions
  • Weight: 0.5 lb.
  • Height: 1.875″
  • Width: 3.125″
  • Length: 4.75″